Summary for Test 2023-08-11-54-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 995022
DEA: 09392104
EFIS: 0922000034
DIST-CO-RTE-PM09--58-R107.7/R118.0
Award Date04/12/2023
Closeout Date11/01/2023
Work DescriptionPlace RHMA-G (Bonded Wearing Course) over existing pavement.
Location DescriptionIN KERN COUNTY ABOUT 17 MILES EAST OF TEHACHAPI FROM 0.1 MILE EAST OF CACHE CREEK BRIDGE TO 1.8 MILES EAST OF BUSINESS ROUTE 58 OVERCROSSING.
QA Service Level1 (Verified on 07/31/2023)

Sample Information

Sample Taken Date08/11/2023 Sample Unique Key54
Date that the sample was received by the laboratory/organization performing the testing09/11/2023 Sample typeDepartment Acceptance
A brief description of the sample1/2" RHMA-G-1% LSM The quantity of what the sample constitutes4 BOXES OF HMA
From where was the sample collectedManufacturer First name of sampler or witnessed bySTUWART
Last name of sampler or witnessed byAhumada Title of sampler
Telephone number of sampler Laboratory sample identification0466G-23
Linked DIME Sample ID The fabricator/manufacturer/facility nameGriffith Edmonston-Lebec
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number1
Sublot number14 HMA Mix NumberGRF20G312RHMALSM
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2023-08-11-54
DIME Test ID: 2023-08-11-54-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-09-15

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Dylan Nault
Date of test: 09/12/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1612.2 g
Mass Loss: 125.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.21 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.19 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.36 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/15/2023 ✔