Summary for Test 2023-09-07-7-1
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 994119 DEA: 033H3904 EFIS: 0317000340 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-5-22.4 |
| Award Date | 09/21/2022 |
| Closeout Date | 04/07/2025 |
| Work Description | STRUCTURAL STEEL BRIDGE AND PRESTRESS STEEL GIRDERS. |
| Location Description | SACRAMENTO COUNTY IN SACRAMENTO AT THE SOUTH CONNECTOR UNDERCROSSING (BRIDGE NO. 24-0267) |
| QA Service Level | 1 (Verified on 07/18/2022) |
Sample Information
| Sample Taken Date | 09/07/2023 | Sample Unique Key | 7 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/11/2023 | Sample type | Quality Assurance |
| A brief description of the sample | 1-8 A563 Nuts | The quantity of what the sample constitutes | 168 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Duben |
| Last name of sampler or witnessed by | Duckworth | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CK Johnson Industries | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 5805574803 | Nut Mfg. Lot Number(s) | 38534-5805574803 |
| Washer Mfg. Lot Number(s) | Bolt Specification | NA | |
| Bolt Length(s) | Nut Specification | ASTM A563 | |
| Washer Specification | NA | Finish | HDG |
| Diameter/Size | 1 | Bolt Mfg. Lot Number | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2023-09-07-7
DIME Test ID: 2023-09-07-7-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2023-09-19
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 09/15/2023
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 98772 | Proof Load |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 9/19/2023 ✔