Summary for Test 2023-08-17-53-4

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 993318
DEA: 11423704
EFIS: 1116000059
DIST-CO-RTE-PM11-SD-8-R31.8/R41.7
Award Date04/01/2022
Closeout Date04/08/2025
Work DescriptionPLACE CRCP, HMA, MGS, AND WATER POLLUTION CONTROL SYSTEM.
Location DescriptionSAN DIEGO COUNTY NEAR ALPINE FROM VIEJAS CREEK BRIDGE TO PINE VALLEY CREEK BRIDGE
QA Service Level1 (Verified on 10/27/2021)

Sample Information

Sample Taken Date08/17/2023 Sample Unique Key53
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/18/2023
Sample typeQuality Assurance A brief description of the sample1/2" HMA
The quantity of what the sample constitutes8 boxes 3 bags From where was the sample collectedSource
First name of sampler or witnessed byJesse Last name of sampler or witnessed byFuentes
Title of sampler Telephone number of sampler
Laboratory sample identification6525-PSU Linked DIME Sample ID2023-08-17-52
The fabricator/manufacturer/facility nameCCA Lakeside Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Hanson Vigilante Rd.
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-08-17-53
DIME Test ID: 2023-08-17-53-4
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2023-10-06

Test Results


How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 08/29/2023
Clay Level (Test 1): 6.7
Sand Level (Test 1): 3.6
Clay Level (Test 2): 6.3
Sand Level (Test 2): 3.6
Clay Level (Test 3): 6.7
Sand Level (Test 3): 3.8
Sand Equivalent (Test 1): 54
Sand Equivalent (Test 2): 58
Sand Equivalent (Test 3): 57
Sand Equivalent: 57
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/6/2023