Summary for Test 2023-07-13-70-5

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 993424
DEA: 04281204
EFIS: 0400000769
DIST-CO-RTE-PM04-NAP-29,221-5.5/6.7,0.0/0.2
Award Date03/21/2022
Closeout DateNot set
Work DescriptionHMA, RDWY EXCAVATION, STRUCTURAL CONC AND MODIFYING LIGHTING SYSTEMS.
Location DescriptionNAPA COUNTY NEAR NAPA ON ROUTE 29 FROM 0.7 MILE SOUTH TO 0.5 MILE NORTH OF ROUTE 221 AND ON ROUTE 221 FROM 0.2 MILE NORTH OF ROUTE 29 TO ROUTE 29
QA Service Level1 (Verified on 12/08/2021)

Sample Information

Sample Taken Date07/13/2023 Sample Unique Key70
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/13/2023
Sample typeQuality Assurance A brief description of the sampleRecycled Class 2 AB
The quantity of what the sample constitutes2500 From where was the sample collectedSource
First name of sampler or witnessed byNick Last name of sampler or witnessed byHall
Title of sampler Telephone number of sampler7072999133
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Napa Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedAbutment 1 G1 Line
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2023-07-13-70
DIME Test ID: 2023-07-13-70-5
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-09-11

Test Results


Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 07/13/2023
Sum of Count or Density: 2577 g/cc
Average of Count or Density: 859 g/cc
Sum of Moisture Count: 1684 g/cc
Average of Moisture Count: 561 g/cc
Count Ratio Density: 1465
Count Ratio Moisture: 644
Calculated Percent Relative Compaction: 93.4 %
Reported Percent Relative Compaction: 93 %
General comments (publicly viewable) (Max 1000 characters): 93%Relative Compaction Failed

Test was verified on 9/11/2023