Summary for Test 2023-08-10-68-8
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 215677 DEA: 044G0804 EFIS: 0412000332 COOP: 042676 |
|---|---|
| DIST-CO-RTE-PM | 04-SOL-80-R10.4/30.2 |
| Award Date | 01/18/2022 |
| Closeout Date | Not set |
| Work Description | Highway widening, overhead signs, and electronic toll system. |
| Location Description | In Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing. |
| QA Service Level | 1 (Verified on 04/11/2022) |
Sample Information
| Sample Taken Date | 08/10/2023 | Sample Unique Key | 68 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/10/2023 |
| Sample type | Quality Assurance | A brief description of the sample | Structure Backfill Native Material |
| The quantity of what the sample constitutes | 2550 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Nick | Last name of sampler or witnessed by | Hall |
| Title of sampler | Telephone number of sampler | 7072999133 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | In Situ Material | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Retaining Wall 5 STA 720 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-08-10-68
DIME Test ID: 2023-08-10-68-8
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-09-11
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 08/10/2023
Sum of Count or Density: 71413 g/cc
Average of Count or Density: 23804 g/cc
Sum of Moisture Count: 7946 g/cc
Average of Moisture Count: 2649 g/cc
Count Ratio Density: 29932
Count Ratio Moisture: 9083
Calculated Percent Relative Compaction: 97.3 %
Reported Percent Relative Compaction: 97 %
General comments (publicly viewable) (Max 1000 characters): 97% Relative Compaction
Passed
Test was verified on 9/11/2023 ✔