Summary for Test 2023-06-28-74-3
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994128 DEA: 043W5304 EFIS: 0421000385 |
---|---|
DIST-CO-RTE-PM | 04-CC-680-1.09 |
Award Date | 01/19/2023 |
Closeout Date | 11/30/2023 |
Work Description | POLYESTER CONCRETE OVERLAY AND GRIND EXISTING CONCRETE PAVEMENT. |
Location Description | BRIDGE DECK PROGRAM |
QA Service Level | 1 (Verified on 08/08/2022) |
Sample Information
Sample Taken Date | 06/28/2023 | Sample Unique Key | 74 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/12/2023 |
Sample type | Quality Assurance | A brief description of the sample | 1/2-INCH HMA Types A and B 25%RAP |
The quantity of what the sample constitutes | Vulcan Pleasanton Drier Drum Plant 25%RAP | From where was the sample collected | Source |
First name of sampler or witnessed by | Nick | Last name of sampler or witnessed by | Hall |
Title of sampler | Telephone number of sampler | 7072999133 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan Pleasanton Drier Drum | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | 320302W |
Test Details
DIME Sample ID: 2023-06-28-74
DIME Test ID: 2023-06-28-74-3
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-09-08
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 07/12/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1532.4 g
Mass Loss: 104.1 g
Correction Factor (Percent by mass of HMA Specimen): 4.7 %
Moisture Content: 0 %
Temperature Compensation Factor: 0.2 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 1.83 %
General comments (publicly viewable) (Max 1000 characters): Vulcan Pleasanton Drier Drum
Sample taken at 00:30
25%RAP Outside Specifications
Test was verified on 9/8/2023 ✔