Summary for Test 2023-07-21-55-7
Test performed: AASHTO T96-02r10Project Information
| Project Identifiers | Project ID: 995048 DEA: 061E5604 EFIS: 0622000066 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-198-21.2/22.7 |
| Award Date | 01/05/2023 |
| Closeout Date | 11/16/2023 |
| Work Description | Cold plane existing asphalt pavement and place RHMA. |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 08/04/2023) |
Sample Information
| Sample Taken Date | 07/21/2023 | Sample Unique Key | 55 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/29/2023 | Sample type | Dispute Resolution |
| A brief description of the sample | 1/2" Aggregate | The quantity of what the sample constitutes | 4 Bags |
| From where was the sample collected | Source | First name of sampler or witnessed by | A. |
| Last name of sampler or witnessed by | M. | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 23-JFMDISP-167 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Granite Colinga | |
| Transportation Laboratory (TL) Number | C027842 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-10-0005 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | HMA Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-07-21-55
DIME Test ID: 2023-07-21-55-7
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2023-09-08
Test Results
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 09/07/2023
Grading designation: C
Mass of sample (before test): 5003 grams
Mass of sample on No.12 sieve (after 100 revolutions): 4717 grams
Mass of sample on No.12 sieve (after 500 revolutions): 3824 grams
Percent loss after 100 revolutions: 6 %
Percent loss after 500 revolutions: 24 %
General comments (publicly viewable) (Max 1000 characters): Los Angeles Rattler, Loss at 100 and 500 Rev.
Test was verified on 9/8/2023 ✔