Summary for Test 2023-08-08-72-5
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994120 DEA: 040J6314 EFIS: 0421000252 |
---|---|
DIST-CO-RTE-PM | 04-SOL-12-21.2/22.6 |
Award Date | 09/16/2022 |
Closeout Date | Not set |
Work Description | ROADWAY RESURFACING, INSTALL DRAINAGE SYSTEM, MIDWEST GUARDRAIL SYSTEM |
Location Description | SOLANO COUNTY NEAR RIO VISTA FROM MCCLOSKY ROAD TO 0.1 MILE WEST OF AZEVEDO ROAD |
QA Service Level | 1 (Verified on 09/13/2022) |
Sample Information
Sample Taken Date | 08/08/2023 | Sample Unique Key | 72 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/17/2023 |
Sample type | Quality Assurance | A brief description of the sample | 1/2-INCH HMA Types A and B W/12%RAP |
The quantity of what the sample constitutes | LOT 1 SUBLOT 2 | From where was the sample collected | Source |
First name of sampler or witnessed by | Nick | Last name of sampler or witnessed by | Hall |
Title of sampler | Telephone number of sampler | 7072999133 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Teichert Vernanlis -Tracy Drum Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | 1 |
Sublot number | 2 | HMA Mix Number | 30240442412V |
Test Details
DIME Sample ID: 2023-08-08-72
DIME Test ID: 2023-08-08-72-5
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-09-08
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 08/17/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1551.1 g
Mass Loss: 102.2 g
Correction Factor (Percent by mass of HMA Specimen): 5.23 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.19 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 1.17 %
General comments (publicly viewable) (Max 1000 characters): LOT 1 SUBLOT 2
Drum Plant 12%RAP
Test was verified on 9/8/2023 ✔