Summary for Test 2023-08-19-33-3
Test performed: AASHTO T209-22Project Information
Project Identifiers | Project ID: 994803 DEA: 043J0704 EFIS: 0415000077 |
---|---|
DIST-CO-RTE-PM | 04-CC-80-10.1/13.5 |
Award Date | 03/10/2023 |
Closeout Date | Not set |
Work Description | Remove PCC and AC, place PCP and AC Resurfacing. |
Location Description | Construction on State Highway in Contra Costa County in Hercules and Crockett from Route 80/4 separation to 0.1 mile west of Crockett Viaduct. |
QA Service Level | 1 (Verified on 05/10/2023) |
Sample Information
Sample Taken Date | 08/19/2023 | Sample Unique Key | 33 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/23/2023 |
Sample type | Quality Assurance | A brief description of the sample | 3/4-INCH RHMA-G CORES |
The quantity of what the sample constitutes | LOT 1 SUBLOT 5 | From where was the sample collected | Source |
First name of sampler or witnessed by | Nick | Last name of sampler or witnessed by | Hall |
Title of sampler | Telephone number of sampler | 7072999133 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan Vallejo Batch Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 5 | HMA Mix Number | 226107 |
Test Details
DIME Sample ID: 2023-08-19-33
DIME Test ID: 2023-08-19-33-3
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-09-07
Test Results
Number of Samples: 2
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 08/23/2023
Specific Gravity for Sample 1: 2.474
Specific Gravity for Sample 2: 2.474
Average Specific Gravity: 2.474
Theoretical maximum density at 25°C (77°F): 2467 kg/m^3
General comments (publicly viewable) (Max 1000 characters): LOT 1 SUBLOT 5
Batch Plant
Test was verified on 9/7/2023 ✔