Summary for Test 2023-08-04-79-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 994803 DEA: 043J0704 EFIS: 0415000077 |
|---|---|
| DIST-CO-RTE-PM | 04-CC-80-10.1/13.5 |
| Award Date | 03/10/2023 |
| Closeout Date | 10/06/2025 |
| Work Description | Remove PCC and AC, place PCP and AC Resurfacing. |
| Location Description | Construction on State Highway in Contra Costa County in Hercules and Crockett from Route 80/4 separation to 0.1 mile west of Crockett Viaduct. |
| QA Service Level | 1 (Verified on 05/10/2023) |
Sample Information
| Sample Taken Date | 08/04/2023 | Sample Unique Key | 79 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/10/2023 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4-inch HMA Types A and B 15% RAP |
| The quantity of what the sample constitutes | LOT 1 SUBLOT 5 | From where was the sample collected | Source |
| First name of sampler or witnessed by | Nick | Last name of sampler or witnessed by | Hall |
| Title of sampler | Telephone number of sampler | 7072999133 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Vulcan Vallejo Drum Plant | Transportation Laboratory (TL) Number | 727295 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | LOT 1 SUBLOT 5 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 5 | HMA Mix Number | 220991W |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-08-04-79
DIME Test ID: 2023-08-04-79-2
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-09-06
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 08/10/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2047.1 g
Mass Loss: 153.9 g
Correction Factor (Percent by mass of HMA Specimen): 5.82 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.12 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 1.58 %
General comments (publicly viewable) (Max 1000 characters): LOT 1 SUBLOT 5
15%RAP
Drier Drum
Test was verified on 9/6/2023 ✔