Summary for Test 2023-07-21-55-1
Test performed: AASHTO T27-14Project Information
| Project Identifiers | Project ID: 995048 DEA: 061E5604 EFIS: 0622000066 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-198-21.2/22.7 |
| Award Date | 01/05/2023 |
| Closeout Date | 11/16/2023 |
| Work Description | Cold plane existing asphalt pavement and place RHMA. |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 08/04/2023) |
Sample Information
| Sample Taken Date | 07/21/2023 | Sample Unique Key | 55 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/29/2023 |
| Sample type | Dispute Resolution | A brief description of the sample | 1/2" Aggregate |
| The quantity of what the sample constitutes | 4 Bags | From where was the sample collected | Source |
| First name of sampler or witnessed by | A. | Last name of sampler or witnessed by | M. |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 23-JFMDISP-167 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Granite Colinga | Transportation Laboratory (TL) Number | C027842 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-10-0005 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | HMA Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-07-21-55
DIME Test ID: 2023-07-21-55-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2023-09-01
Test Results
What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Individual Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 08/31/2023
| Individual Mass Retained | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 3508.2 grams | ||||||
| grams | % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 10.5 grams | 100 % | |||||
| 78.3 grams | 97 % | |||||
| 421.9 grams | 85 % | |||||
| 1154.6 grams | 53 % | |||||
| 917.4 grams | ||||||
| 403.0 grams | 30 % | |||||
| 188.0 grams | 19 % | |||||
| 100.5 grams | 13 % | |||||
| 80.2 grams | 8 % | |||||
| 60.4 grams | 5 % | |||||
| 40.0 grams | 2.6 % | |||||
| 4.4 grams | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/1/2023 ✔