Summary for Test 2017-02-08-1-2
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 210808 DEA: 020E0904 EFIS: 0200000016 |
|---|---|
| DIST-CO-RTE-PM | 02-SHA-5-R29.3/R31.1,R45.0/R45.8 |
| Award Date | 02/03/2016 |
| Closeout Date | 10/21/2020 |
| Work Description | REPLACE BRIDGE, REALIGN ROADWAY AND SEISMIC RETROFIT |
| Location Description | IN SHASTA COUNTY ABT 8 MI N OF SHASTA LAKE CTY AND NEAR LAKEHEAD FRM TURNTABLE BAY O/C TO 0.1 MI N OF O'BRIEN SRRA & FRM 0.4 MI S TO 0.3 MI N OF DOG CREEK BRIDGE. |
| QA Service Level | 1 (Verified on 09/23/2015) |
Sample Information
| Sample Taken Date | 02/08/2017 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/08/2017 |
| Sample type | Quality Assurance | A brief description of the sample | Stainless Steel |
| The quantity of what the sample constitutes | 2 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Corey | Last name of sampler or witnessed by | Gardner |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Contractor Materials Company | Transportation Laboratory (TL) Number | C704031 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | North American Stainless |
| Coupler Manufacturer | North American Stainless | Intermediate Assembler or Fabricator | Unknown |
| Rebar Size | #8 | Coupler Model | Threaded stainless Coupler |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
| Coupler Component Heat/Lot Number(s) | M9P1 | Rebar Heat Number(s) | Y1E0 |
| Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2017-02-08-1
DIME Test ID: 2017-02-08-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2017-03-01
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 02/10/2017
UTM: 400KIP
Temperature: 72 F
Halo ID: Small
| Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 10000 | #8/25mm Stainless steel | 1 | 0 | 0.79 | 82911 | 104950 | Pull out of coupler | Fred |
General comments (publicly viewable) (Max 1000 characters): Pull out of coupler
Test Graph
Source: Partner Data Point FileTest was verified on 2/22/2017 ✔