Summary for Test 2017-01-04-5-7
Test performed: ASTM C204-11Project Information
| Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 01/04/2017 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/11/2017 | Sample type | Annual Source Testing |
| A brief description of the sample | Type II/V | The quantity of what the sample constitutes | 15 lbs |
| From where was the sample collected | Source | First name of sampler or witnessed by | Unknown |
| Last name of sampler or witnessed by | unknown | Title of sampler | Unknown |
| Telephone number of sampler | Unknown | Laboratory sample identification | CM175707 |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Unknown |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Cementitious | Brand | Salt River Materials Group |
|---|---|---|---|
| Mill | Clarkdale | Type of Cementitious Material | Type II/V Cement |
Test Details
DIME Sample ID: 2017-01-04-5
DIME Test ID: 2017-01-04-5-7
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus
Test Release Date: 2018-07-17
Test Results
Input Type: Measured
Tester's full name: timothy omalley
Date of test: 02/10/2017
Test Time: 104 seconds
Method Used: Test Method A
Fineness: 4068 cm^2/g
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/17/2018 ✔