Summary for Test 2017-01-04-5-7

Test performed: ASTM C204-11

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date01/04/2017 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing01/11/2017 Sample typeAnnual Source Testing
A brief description of the sampleType II/V The quantity of what the sample constitutes15 lbs
From where was the sample collectedSource First name of sampler or witnessed byUnknown
Last name of sampler or witnessed byunknown Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationCM175707
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameUnknown
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeCementitious BrandSalt River Materials Group
MillClarkdale Type of Cementitious MaterialType II/V Cement

Test Details

DIME Sample ID: 2017-01-04-5
DIME Test ID: 2017-01-04-5-7
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus
Test Release Date: 2018-07-17

Test Results


Input Type: Measured
Tester's full name: timothy omalley
Date of test: 02/10/2017
Test Time: 104 seconds
Method Used: Test Method A
Fineness: 4068 cm^2/g
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/17/2018