Summary for Test 2023-08-29-7-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 994454
DEA: 010M7304
EFIS: 0123000063
DIST-CO-RTE-PM01-HUM-211-77.2/78.59999999999999
Award Date12/21/2022
Closeout DateNot set
Work DescriptionFernbridge Earthquake Restoration (Bridge No. 04-0134)
Location DescriptionNot set
QA Service Level1 (Verified on 01/03/2023)

Sample Information

Sample Taken Date08/29/2023 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing08/29/2023 Sample typeQuality Assurance
A brief description of the sampleGriptwist Couplers The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byR
Last name of sampler or witnessed byDuran Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameBarSplice
Transportation Laboratory (TL) Numberc972255 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCascade
Coupler ManufacturerBarSplice Intermediate Assembler or Fabricator
Rebar Size#11 Coupler ModelTaper GripTwist
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)A222815/C216089 Rebar Heat Number(s)213523
Rebar Size 2 Coupler Unique IDSS-17-03

Test Details

DIME Sample ID: 2023-08-29-7
DIME Test ID: 2023-08-29-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2023-08-29

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 08/29/2023
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 11/36mm101.5614839195123Service Spliceaauvinen

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 8/29/2023 ✔