Summary for Test 2017-01-25-5-1
Test performed: ASTM A722-15Project Information
| Project Identifiers | Project ID: 211768 DEA: 043K1104 EFIS: 0417000079 |
|---|---|
| DIST-CO-RTE-PM | 04-SF-80-8.3, 8.30 |
| Award Date | 10/10/2016 |
| Closeout Date | 10/17/2019 |
| Work Description | Replace SAS tower anchor rod grout |
| Location Description | Bay Bridge |
| QA Service Level | 1 (Verified on 01/09/2017) |
Sample Information
| Sample Taken Date | 01/25/2017 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/31/2017 |
| Sample type | Quality Assurance | A brief description of the sample | Williams Thread Bars |
| The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Bahjat | Last name of sampler or witnessed by | Dagher |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Williams Form | Transportation Laboratory (TL) Number | C953154 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L9300217 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Threaded Bar Specification | ASTM A722 | Threaded Bar Grade | 150 |
| Threaded Bar Type | Deformed | Rebar Size | 2.25" |
| Nut Specification for Threaded Bar | A722 | System Manufacturer | Williams form |
| Epoxy Coating Color | NA | Threaded Bar Application | Threaded Bar |
| Coating Standards | Uncoated | Bar Heat Number(s) | NF15204277 |
| Nut Heat Number(s) | MM12102758 | Bar Lot Number | Unknown |
| Nut Lot Number | Unknown | Coupler Heat Number(s) | MM16100365 |
| Coupler Grade | A722 |
Test Details
DIME Sample ID: 2017-01-25-5
DIME Test ID: 2017-01-25-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2017-02-09
Test Results
Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: Fred / Brian
Date of test: 02/02/2017
UTM: 2000KIP
Temperature: 72 F
| Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | A722 Williams Form 2.250\" x 6\' Threaed Bar | Heat #NF15204277 | 3.75 | 158510 | 148860 | 4 | 45 | A722 Bar & Nut | Fred / Brian |
General comments (publicly viewable) (Max 1000 characters): A722 Bar & Nut
Test Graph
WARNING: No graph data imported from Instron machine.
Test was verified on 2/2/2017 ✔