Summary for Test 2023-08-24-23-1
Test performed: AASHTO T176-08Project Information
| Project Identifiers | Project ID: 214493 DEA: 07311704 EFIS: 0715000013 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-134-0.0/R13.3 |
| Award Date | 04/16/2020 |
| Closeout Date | 07/09/2024 |
| Work Description | CONCRETE SLAB REPLACEMENT, HMA PAVING, ELECTRICAL AND LANDSCAPE WORK. |
| Location Description | LOS ANGELES COUNTY IN LOS ANGELES, BURBANK, GLENDALE AND PASADENA FROM ROUTE 101/134 SEPARATION TO JUNCTION OF ROUTE 210/710 |
| QA Service Level | 1 (Verified on 04/15/2020) |
Sample Information
| Sample Taken Date | 08/24/2023 | Sample Unique Key | 23 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/25/2023 | Sample type | Quality Assurance |
| A brief description of the sample | Coldfeed Blend | The quantity of what the sample constitutes | 800 |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Cameron |
| Last name of sampler or witnessed by | Massa | Title of sampler | Field Materials Tester |
| Telephone number of sampler | 9093744210 | Laboratory sample identification | 23-08-008 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | All American Asphalt - Irwindale | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0005 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Conveyor Belt | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | 106836 | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-08-24-23
DIME Test ID: 2023-08-24-23-1
Testing Lab: Kleinfelder, Incorporated - Los Angeles
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2023-08-28
Test Results
How many times will the test be run?: 3 Times
Input Type: Calculated
Tester's full name: Cameron Massa
Date of test: 08/25/2023
Sand Equivalent (Test 1): 73
Sand Equivalent (Test 2): 71
Sand Equivalent (Test 3): 72
Sand Equivalent: 72
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/28/2023 ✔