Summary for Test 2023-07-28-37-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 993333 DEA: 04264724 EFIS: 0419000068 |
---|---|
DIST-CO-RTE-PM | 04-MRN-101-R20.8/27.1 |
Award Date | 04/26/2022 |
Closeout Date | Not set |
Work Description | CIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL. |
Location Description | MARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE |
QA Service Level | 1 (Verified on 11/01/2021) |
Sample Information
Sample Taken Date | 07/28/2023 | Sample Unique Key | 37 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/29/2023 |
Sample type | Quality Assurance | A brief description of the sample | 3 4x8 concrete cylinder molds |
The quantity of what the sample constitutes | RW1 Footing | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Dhiren | Last name of sampler or witnessed by | Rajmohan |
Title of sampler | Assistant Structure Representative | Telephone number of sampler | 15103856774 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Shamrock Materials Petaluma | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Retaining Wall 1 |
Material Information
Material Type | Concrete | The concrete mix design number | SL-4201CG |
---|---|---|---|
The truck number from where the sample was collected | 2438 | The batch plant ticket number from where the sample was collected | 397396 |
Concrete batch plant | 138 Petaluma | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | CHUTE FROM TRUCK | Where the material sample would have been placed if not sampled | RW1 Footing |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-07-28-37
DIME Test ID: 2023-07-28-37-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2023-08-25
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: SA
Date of test: 08/25/2023
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 4.02 in
Average diameter of cylinder 2: 4.03 in
Average diameter of cylinder 3: 4.04 in
Maximum load on cylinder 1: 59583 lbf
Maximum load on cylinder 2: 66696 lbf
Maximum load on cylinder 3: 67656 lbf
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 12.69 in^2
Cross sectional area of cylinder 2: 12.76 in^2
Cross sectional area of cylinder 3: 12.82 in^2
Compressive strength of cylinder 1: 4694.0 psi
Compressive strength of cylinder 2: 5229.0 psi
Compressive strength of cylinder 3: 5278 psi
Compressive strength (to nearest 10 psi): 5070 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for Cylinder Code 1 of 3
Source: Bluehill Data Point File
Test graph for Cylinder Code 2 of 3
Source: Bluehill Data Point File
Test graph for Cylinder Code 3 of 3
Test was verified on 8/25/2023 ✔