Summary for Test 2017-01-19-4-4
Test performed: ASTM D2628-91-re11-lowProject Information
| Project Identifiers | Project ID: 8196 DEA: 59912684 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | |
| Location Description | |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 01/19/2017 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/23/2017 |
| Sample type | Quality Assurance | A brief description of the sample | Joint Seal |
| The quantity of what the sample constitutes | 550ft | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Simon |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Watson Bowman | Transportation Laboratory (TL) Number | NA |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM2 - Type B Elastomeric Joint Seal | Mfg. Lot Number(s) | 0217111 |
|---|---|---|---|
| Manufacturer(s) | Watson Bowman | Temperature | 72 |
| Humidity | 50 | Comments | Unknown |
| Joint Seal Size | 3.75 |
Test Details
DIME Sample ID: 2017-01-19-4
DIME Test ID: 2017-01-19-4-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D2628-91-re11-low: Standard Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements (Low Temp Recovery)
Test Release Date: 2017-02-13
Test Results
Input Type: Measured
Tester's full name: Brian Ewing
Date of test: 01/31/2017
Temperature: 72 f
Humidity: 50 %
Low Temp Recovery (22 hrs at -20F) Size Before (Height of Contact Face ): 3.75 in
Low Temp Recovery (22 hrs at -20F) Size After (Recovered Contact Face ): 3.502 in
Percent Recovery (Low Temp): 93 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/6/2017 ✔