Summary for Test 2023-08-03-50-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 994296
DEA: 07336004
EFIS: 0716000375
DIST-CO-RTE-PM07-VEN-118-R1.4/1.8
Award Date12/07/2022
Closeout DateNot set
Work DescriptionCONSTRUCT STORMWATER TREATMENT DEVICES.
Location DescriptionIN VENTURA COUNTY NEAR SATICOY FROM 0.2 MILE EAST OF NARDO STREET TO 0.1 MILE WEST OF SANTA CLARA RIVER
QA Service Level1 (Verified on 10/06/2022)

Sample Information

Sample Taken Date08/03/2023 Sample Unique Key50
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/04/2023
Sample typeDepartment Acceptance A brief description of the sample4X8 PCC cylinders
The quantity of what the sample constitutes130 CY From where was the sample collectedJob Site
First name of sampler or witnessed byJessica Last name of sampler or witnessed byCisneros
Title of samplerAssistant Structure Representative Telephone number of sampler
Laboratory sample identification23-346 Linked DIME Sample ID
The fabricator/manufacturer/facility nameNational Ready Mix Concrete Company Transportation Laboratory (TL) Number080323
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberS85C440T14
The truck number from where the sample was collected8 The batch plant ticket number from where the sample was collected626217
Concrete batch plantNational Ready Mix Concrete Company The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedtruck chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-08-03-50
DIME Test ID: 2023-08-03-50-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-08-24

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Robert Achuela
Date of test: 08/24/2023
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.02 in
Average diameter of cylinder 2: 4.02 in
Average diameter of cylinder 3: 4.02 in
Maximum load on cylinder 1: 68469 lb
Maximum load on cylinder 2: 65989 lb
Maximum load on cylinder 3: 70416 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 21 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.69 in^2
Cross sectional area of cylinder 2: 12.69 in^2
Cross sectional area of cylinder 3: 12.69 in^2
Compressive strength of cylinder 1: 5395.5 psi
Compressive strength of cylinder 2: 5200.1 psi
Compressive strength of cylinder 3: 5548.9 psi
Compressive strength (to nearest 10 psi): 5380 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/24/2023