Summary for Test 2017-01-19-1-5
Test performed: ASTM D2628-91-re11-highProject Information
Project Identifiers | Project ID: 8196 DEA: 59912684 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | |
Location Description | |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 01/19/2017 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/23/2017 |
Sample type | Quality Assurance | A brief description of the sample | Joint Seal |
The quantity of what the sample constitutes | 500ft | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Simon |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Watson Bowman | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM2 - Type B Elastomeric Joint Seal | Mfg. Lot Number(s) | 0117110 |
---|---|---|---|
Manufacturer(s) | Watson Bowman | Temperature | 72 |
Humidity | 50 | Comments | Unknown |
Joint Seal Size | 2.75 |
Test Details
DIME Sample ID: 2017-01-19-1
DIME Test ID: 2017-01-19-1-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D2628-91-re11-high: Standard Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements (High Temp Recovery)
Test Release Date: 2017-02-13
Test Results
Input Type: Measured
Tester's full name: Brian Ewing
Date of test: 01/27/2017
Temperature: 72 f
Humidity: 50 %
High Temp Recovery (70 hrs at 212F) Size Before (Height of Contact Face ): 2.75 in
High Temp Recovery (70 hrs at 212F) Size After (Expanded Contact Face ): 2.716 in
Percent Recovery (High Temp): 99 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/6/2017 ✔