Summary for Test 2023-07-25-77-4

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994936
DEA: 051P1604
EFIS: 0521000179
DIST-CO-RTE-PM05---
Award DateNot set
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 06/28/2023)

Sample Information

Sample Taken Date07/25/2023 Sample Unique Key77
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/11/2023
Sample typeDispute Resolution A brief description of the sample3/4 RHMA-G
The quantity of what the sample constitutes5 Boxes RHMA, 2 Cans of Binder, 2 bags of aggregate From where was the sample collectedSource
First name of sampler or witnessed byIsaac Last name of sampler or witnessed byLarey-Chezem
Title of samplerTET Telephone number of sampler
Laboratory sample identification023-047 Linked DIME Sample ID2023-07-25-75
The fabricator/manufacturer/facility nameSPM-Templeton Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number1
Sublot number1 HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2023-07-25-77
DIME Test ID: 2023-07-25-77-4
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-08-24

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Glenn Bradley
Date of test: 08/23/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 4218.1 g
Mass of the specimen and specimen basket assembly prior to ignition: 6463.6 g
Mass of HMA Sample prior to ignition: 2245.5 g
Mass Loss: 188.9 g
Mass of aggregate remaining after ignition: 2056.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.92 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.16 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.33 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/24/2023