Summary for Test 2023-08-15-31-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994780
DEA: 070W3304
EFIS: 0721000265
DIST-CO-RTE-PM07-LA-10-19.5/29.5
Award Date03/13/2023
Closeout Date03/14/2025
Work DescriptionLOS ANGELES COUNTY FROM EVERGREEN AVENUE PEDESTRIAN OVERCROSSING IN LOS ANGELES TO VALLEY BOULEVARD UNDERCROSSING IN EL MONTE
Location DescriptionDIGOUTS, SLURRY SEAL, COLD PLANE OVERLAY,
QA Service Level1 (Verified on 06/07/2023)

Sample Information

Sample Taken Date08/15/2023 Sample Unique Key31
Date that the sample was received by the laboratory/organization performing the testing08/17/2023 Sample typeDepartment Acceptance
A brief description of the sample3/4" RHMA-G-SP 0.5% LAS The quantity of what the sample constitutes4 BOXES OF RHMA
From where was the sample collectedManufacturer First name of sampler or witnessed byGERAEDO
Last name of sampler or witnessed byZubieta Title of sampler
Telephone number of sampler Laboratory sample identification0417G-23
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Irwindale
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number226108M IRW LTR
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2023-08-15-31
DIME Test ID: 2023-08-15-31-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-08-23

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Dylan Nault
Date of test: 08/19/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2123.0 g
Mass Loss: 175.0 g
Correction Factor (Percent by mass of HMA Specimen): -0.41 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.69 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/23/2023 ✔