Summary for Test 2023-08-16-53-1

Test performed: AASHTO T59-22

Project Information

Project IdentifiersProject ID: 994854
DEA: 061E5804
EFIS: 0622000071
DIST-CO-RTE-PM06-KER-43,46-9.0/15.7, 20.0/27.5
Award Date03/28/2023
Closeout Date11/16/2023
Work DescriptionFOR CONSTRUCTION ON STATE HIGHWAY IN KERN COUNTY NEAR WASCO ON ROUTE 43 FROM 0.2 MILE SOUTH OF ROUTE 58 TO 0.5 MILE NORTH OF RIVERSIDE AVENUE AND ROUTE 46 FROM 0.5 MILE WEST OF ROUTE 33 TO HOLLOWAY ROAD
Location DescriptionIn District 06 On Route 43, 46
QA Service Level1 (Verified on 06/14/2023)

Sample Information

Sample Taken Date08/16/2023 Sample Unique Key53
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/21/2023
Sample typeDepartment Acceptance A brief description of the samplecss-1h
The quantity of what the sample constitutes1 of 1 From where was the sample collectedJob Site
First name of sampler or witnessed bys Last name of sampler or witnessed byFelix
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTalley Oil Transportation Laboratory (TL) Number754664
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeCSS-1h
Lot NumberNot set Sub LotNot set
Dilution Percentage RateNot set

Test Details

DIME Sample ID: 2023-08-16-53
DIME Test ID: 2023-08-16-53-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2023-08-23

Test Results


How many beakers will be used to conduct the test?: 4
Input Type: Measured
Tester's full name: Alonso Lopez-Sanchez
Date of test: 08/23/2023
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 125.5 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 112.2 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 125.0 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 111.7 g
Beaker 3 Mass of beaker, rod, screen (if used), and residue: 126.1 g
Beaker 3 Tare mass of the beaker, rod, and screen (if used): 112.3 g
Beaker 4 Mass of beaker, rod, screen (if used), and residue: 125.6 g
Beaker 4 Tare mass of the beaker, rod, and screen (if used): 112.0 g
Beaker 1 Residue: 26.6 %
Beaker 2 Residue: 26.6 %
Beaker 3 Residue: 27.6 %
Beaker 4 Residue: 27.2 %
Percentage of residue: 27 %
General comments (publicly viewable) (Max 1000 characters): evap

Test was verified on 8/23/2023