Summary for Test 2023-07-26-71-3

Test performed: ASTM D5329-16

Project Information

Project IdentifiersProject ID: 994998
DEA: 061E5704
EFIS: 0622000070
DIST-CO-RTE-PM06-FRE-145-26.1/34/1, 2.0/8.0
Award Date04/18/2023
Closeout Date02/26/2024
Work DescriptionCold plane asphalt concrete pavement and place RHMA.
Location DescriptionFOR CONSTRUCTION ON STATE HIGHWAY IN FRESNO COUNTY IN AND NEAR KERMAN FROM MANNING AVENUE TO 0.1 MILE SOUTH OF CALIFORNIA AVENUE AND IN THE CITY AND COUNTY OF MADERA FROM 0.1 MILE NORTH OF AVENUE 7 TO 0.1 MILE SOUTH OF AVENUE 13
QA Service Level1 (Verified on 08/15/2023)

Sample Information

Sample Taken Date07/26/2023 Sample Unique Key71
Date that the sample was received by the laboratory/organization performing the testing08/10/2023 Sample typeDepartment Acceptance
A brief description of the samplerubber binder can The quantity of what the sample constitutes1 Can
From where was the sample collectedSource First name of sampler or witnessed byUnknown
Last name of sampler or witnessed byUnknown Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSan Joaquin Refinery
Transportation Laboratory (TL) Number027215 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number2
Sublot number4 Asphalt Rubber Binder Mix Number

Test Details

DIME Sample ID: 2023-07-26-71
DIME Test ID: 2023-07-26-71-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2023-08-23

Test Results


Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 08/18/2023
Temperature: 25 C
Ball Penetration (P1): 2 mm
Final Dial reading (F1): 71 mm
Ball Penetration (P2): 1 mm
Final Dial reading (F2): 67 mm
Ball Penetration (P3): 2 mm
Final Dial reading (F3): 69 mm
Resilience 1: 31 %
Resilience 2: 34 %
Resilience 3: 33 %
Average Resilience: 33 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/23/2023 ✔