Summary for Test 2023-07-05-64-7
Test performed: CTM 556-January 2018Project Information
Project Identifiers | Project ID: 215425 DEA: 06360244 EFIS: 0613000005 |
---|---|
DIST-CO-RTE-PM | 06-TUL-99-30.6/35.2 |
Award Date | 04/23/2021 |
Closeout Date | Not set |
Work Description | Widen Freeway & Bridge Construction (Concrete Bridge) |
Location Description | Not set |
QA Service Level | 1 (Verified on 11/01/2021) |
Sample Information
Sample Taken Date | 07/05/2023 | Sample Unique Key | 64 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/06/2023 |
Sample type | Quality Control | A brief description of the sample | 4x8 concrete cylinders |
The quantity of what the sample constitutes | 7 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Alvaro | Last name of sampler or witnessed by | Pineda |
Title of sampler | QC Field Tech | Telephone number of sampler | |
Laboratory sample identification | Set 1 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Job Site | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 85Q41S0P |
---|---|---|---|
The truck number from where the sample was collected | Load 1 | The batch plant ticket number from where the sample was collected | 0 |
Concrete batch plant | The fabricator/manufacturer designation for the sample | Set 1 | |
A detailed description of where the material sample was collected | Jst Bridge Back Wall and PT Blockout | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-07-05-64
DIME Test ID: 2023-07-05-64-7
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement Concrete
Test Release Date: 2023-08-18
Test Results
Input Type: Calculated
Tester's full name: Alvaro Pineda
Date of test: 07/05/2023
Slump: 4.5 inch
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/18/2023 ✔