Summary for Test 2023-06-26-50-7
Test performed: AASHTO T335-09r13Project Information
| Project Identifiers | Project ID: 994749 DEA: 120T6504 EFIS: 1222000075 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-57-11.5/18.6 |
| Award Date | 01/12/2023 |
| Closeout Date | 02/02/2024 |
| Work Description | Cold plane AC Pavement and place RHMA. |
| Location Description | FOR CONSTRUCTION ON STATE HIGHWAY IN ORANGE COUNTY IN ORANGE, ANAHEIM, PLACENTIA, AND FULLERTON FROM 0.2 MILE SOUTH OF ORANGEWOOD AVENUE UNDERCROSSING TO 0.3 MILE NORTH OF YORBA LINDA BOULEVARD OVERCROSSING AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 07/07/2023) |
Sample Information
| Sample Taken Date | 06/26/2023 | Sample Unique Key | 50 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/29/2023 |
| Sample type | Verification | A brief description of the sample | PSUE 1/2" RHMA-G-SP 0.25% EVO |
| The quantity of what the sample constitutes | 3 Bags of Aggregate | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | R J Noble | Last name of sampler or witnessed by | QC |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0345G-23 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | R J Noble Orange | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0014, 91-33-0035 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Belt Cut at R J Noble- Orange | |
| Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 1/2 inch |
| The concrete mix design number | 50R003ARSPWEO | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-06-26-50
DIME Test ID: 2023-06-26-50-7
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2023-09-19
Test Results
Method: 1 - Combined Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced and Fine 1 Faced
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 07/07/2023
Percentage of fractured, coarse, 2 faced particles tested: 100 %
Percentage of fractured, coarse, 1 faced particles tested: 100 %
Percentage of fractured, fine, 1 faced particles tested: 100 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/19/2023 ✔