Summary for Test 2017-01-19-2-2

Test performed: ASTM D2240-05re10

Project Information

Project IdentifiersProject ID: 8196
DEA: 59912684
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work Description
Location Description
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date01/19/2017 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing01/23/2017 Sample typeQuality Assurance
A brief description of the sampleJoint Seal The quantity of what the sample constitutes550ft
From where was the sample collectedManufacturer First name of sampler or witnessed byDavid
Last name of sampler or witnessed bySimon Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameWatson Bowman
Transportation Laboratory (TL) NumberNA Inspector Lot Number from the Transportation Laboratory (TL) FormNA
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM2 - Type B Elastomeric Joint Seal Mfg. Lot Number(s)0117111
Manufacturer(s)Watson Bowman Temperature72
Humidity50 CommentsUnknown
Joint Seal Size3.75

Test Details

DIME Sample ID: 2017-01-19-2
DIME Test ID: 2017-01-19-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Test Release Date: 2017-02-13

Test Results


Input Type: Measured
Tester's full name: Brian Ewing
Date of test: 01/26/2017
Temperature: 72 f
Humidity: 50 %
Reading #1: 54
Reading #2: 56
Reading #3: 55
Reading #4: 56
Reading #5: 54
Mean: 55
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/6/2017 ✔