Summary for Test 2023-08-14-40-2
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 993806 DEA: 07330504 EFIS: 0716000214 |
---|---|
DIST-CO-RTE-PM | 07-LA-710-R15.1/21.9 |
Award Date | 08/02/2022 |
Closeout Date | Not set |
Work Description | INSTALL HIGHWAY PLANTING AND PLACE MINOR CONCRETE. |
Location Description | LOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM 0.2 MILE NORTH OF ROSECRANS AVENUE TO 0.1 MILE SOUTH OF ATLANTIC AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 05/11/2022) |
Sample Information
Sample Taken Date | 08/14/2023 | Sample Unique Key | 40 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/15/2023 |
Sample type | Department Acceptance | A brief description of the sample | 3/4" RHMA-G 226108M IRW LTR |
The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | MD | Last name of sampler or witnessed by | Shahjahan |
Title of sampler | MREA | Telephone number of sampler | |
Laboratory sample identification | 23-365 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Materials Irwindale | Transportation Laboratory (TL) Number | 019567 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | 226108M IRW LTR |
Test Details
DIME Sample ID: 2023-08-14-40
DIME Test ID: 2023-08-14-40-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-08-16
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Chad Chotibhongs
Date of test: 08/16/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 4027.1 g
Mass of the specimen and specimen basket assembly prior to ignition: 6113.2 g
Mass of HMA Sample prior to ignition: 2086.1 g
Mass Loss: 166.1 g
Mass of aggregate remaining after ignition: 1920.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.25 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.71 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/16/2023 ✔