Summary for Test 2023-08-07-4-2

Test performed: ASTM A970-18

Project Information

Project IdentifiersProject ID: 214830
DEA: 043G6304
EFIS: 0412000409
DIST-CO-RTE-PM04-SCL-4-SCl-9 -4.75/4.9
Award Date11/08/2022
Closeout DateNot set
Work DescriptionSaratoga Creek Bridge Rehabilitation Project
Location DescriptionSan Jose - Saratoga Creek
QA Service Level1 (Verified on 11/09/2020)

Sample Information

Sample Taken Date08/07/2023 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/15/2023
Sample typeQuality Assurance A brief description of the sample#9 Headed Bar
The quantity of what the sample constitutes10 From where was the sample collectedFabricator
First name of sampler or witnessed byEDWARD Last name of sampler or witnessed byLEACH
Title of sampler Telephone number of sampler7072903887
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCamblin Steel Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)3500031329 Head Manufacturer Lot Number(s)N/A
Rebar Size#9 Headed Bar Model NameHRC Type 555
Size of HeadReduced Size - 4x Head Connection TypeForged
Head ShapeCircular Rebar ManufacturerNuccor
Head ManufacturerCamblin Steel Head FabricatorCamblin Steel
Material Standard CodeASTM A706 Headed Bar Unique ID4FG-17-01

Test Details

DIME Sample ID: 2023-08-07-4
DIME Test ID: 2023-08-07-4-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2023-08-17

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 08/16/2023
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
1119192491924Ok Neckingaauvinen

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 8/17/2023