Summary for Test 2023-08-02-13-1
Test performed: ASTM C39-17aProject Information
| Project Identifiers | Project ID: 994842 DEA: 043Y5304 EFIS: 0423000258 |
|---|---|
| DIST-CO-RTE-PM | 04-SON-1-38.25, 38.25/38.25 |
| Award Date | 04/14/2023 |
| Closeout Date | Not set |
| Work Description | Slope stabilization |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 05/22/2023) |
Sample Information
| Sample Taken Date | 08/02/2023 | Sample Unique Key | 13 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/08/2023 | Sample type | Quality Assurance |
| A brief description of the sample | Soldier Pile Concrete Backfill Wet Mix | The quantity of what the sample constitutes | 10cy |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Richard |
| Last name of sampler or witnessed by | Jones | Title of sampler | ASR |
| Telephone number of sampler | 530-941-4305 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Canyon Rock - Forestville | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | Ocean Cove Retaining Wall | |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 72203043F |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | TBD | |
| Concrete batch plant | Forestville Canyon Rock | The fabricator/manufacturer designation for the sample | Wet Hole Concrete Backfill |
| A detailed description of where the material sample was collected | Chute | Where the material sample would have been placed if not sampled | Soldier Piles4and8 |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-08-02-13
DIME Test ID: 2023-08-02-13-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2023-08-16
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Spencer Adams
Date of test: 08/16/2023
Capped in accordance with?: ASTM C39 - Ground End
Average diameter of cylinder 1: 3.99 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 54566 lb
Maximum load on cylinder 2: 55577 lb
Maximum load on cylinder 3: 56504 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 14 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 12.5 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 4365.3 psi
Compressive strength of cylinder 2: 4400.4 psi
Compressive strength of cylinder 3: 4473.8 psi
Compressive strength (to nearest 10 psi): 4410 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/16/2023 ✔