Summary for Test 2023-06-14-95-2
Test performed: AASHTO T209-22Project Information
| Project Identifiers | Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for storing JMF sample data |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 06/14/2023 | Sample Unique Key | 95 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/15/2023 |
| Sample type | Verification | A brief description of the sample | 2 bags of Fine RAP (3/8-inch) |
| The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Ward | Last name of sampler or witnessed by | Jenkins |
| Title of sampler | Not set | Telephone number of sampler | Not set |
| Laboratory sample identification | Not set | Linked DIME Sample ID | Not set |
| The fabricator/manufacturer/facility name | Hat Creek Construction and Materials - Ward Lake Plant - Litchfield, CA | Transportation Laboratory (TL) Number | Not set |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Ward Lake Plant |
|---|---|---|---|
| Aggregate Size | Not set | Aggregate Source | Not set |
| RAP Stockpile | Not set | Stockpile Size (tons) | Not set |
| Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2023-06-14-95
DIME Test ID: 2023-06-14-95-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-08-16
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 06/22/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7335.7 grams
Mass of oven-dry sample in air for Sample 1: 1602.5 grams
Mass of container filled with the sample and water for Sample 1: 8294.9 grams
Temperature of Water: 76.5 °F
Specific Gravity for Sample 1: 2.491
Theoretical maximum density at 25°C (77°F): 2484 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmmr=2.491
Test was verified on 8/16/2023 ✔