Summary for Test 2023-08-04-54-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 994998
DEA: 061E5704
EFIS: 0622000070
DIST-CO-RTE-PM06-FRE-145-26.1/34/1, 2.0/8.0
Award Date04/18/2023
Closeout Date02/26/2024
Work DescriptionCold plane asphalt concrete pavement and place RHMA.
Location DescriptionFOR CONSTRUCTION ON STATE HIGHWAY IN FRESNO COUNTY IN AND NEAR KERMAN FROM MANNING AVENUE TO 0.1 MILE SOUTH OF CALIFORNIA AVENUE AND IN THE CITY AND COUNTY OF MADERA FROM 0.1 MILE NORTH OF AVENUE 7 TO 0.1 MILE SOUTH OF AVENUE 13
QA Service Level1 (Verified on 08/15/2023)

Sample Information

Sample Taken Date08/04/2023 Sample Unique Key54
Date that the sample was received by the laboratory/organization performing the testing08/04/2023 Sample typeDepartment Acceptance
A brief description of the sample1/2 HMA Cold Feed The quantity of what the sample constitutes750 Tons
From where was the sample collectedManufacturer First name of sampler or witnessed byNoah
Last name of sampler or witnessed byHunt Title of samplerConsultant
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite Coalinga HMA Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Granite Coalinga
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number2
Sublot number24 Aggregate Mix Number

Test Details

DIME Sample ID: 2023-08-04-54
DIME Test ID: 2023-08-04-54-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2023-08-15

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 08/04/2023
Cumulative Mass RetainedCumulative Percent Passing
4246.0 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
24.0 grams99 %
767.0 grams82 %
2517.0 grams41 %
490.6 grams
211.8 grams23 %
306.4 grams15 %
361.5 grams11 %
404.2 grams7 %
438.2 grams4 %
458.2 grams2.7 %
460.0 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/15/2023 ✔