Summary for Test 2023-07-31-66-1

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 993141
DEA: 060V1204
EFIS: 0616000207
DIST-CO-RTE-PM06-MAD-99-R6.9/R7.6
Award Date06/22/2022
Closeout Date12/02/2025
Work DescriptionCottonwood Creek Bridge Replacement - REPLACE BRIDGES AND CONSTRUCT RETAINING WALLS.
Location DescriptionMADERA COUNTY NEAR MADERA FROM 0.4 MILE SOUTH OF COTTONWOOD CREEK BRIDGE TO 0.1 MILE NORTH OF AVENUE 12 OVERCROSSING
QA Service Level1 (Verified on 07/28/2021)

Sample Information

Sample Taken Date07/31/2023 Sample Unique Key66
Date that the sample was received by the laboratory/organization performing the testing08/01/2023 Sample typeDepartment Acceptance
A brief description of the sample4x8 concrete cylinders The quantity of what the sample constitutespcc
From where was the sample collectedJob Site First name of sampler or witnessed byBandy
Last name of sampler or witnessed byAHMED Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameBuilders Concrete Ready Mix Plant Sanger
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberND22023
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected0000000000000000
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete from wheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-07-31-66
DIME Test ID: 2023-07-31-66-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2023-08-14

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 08/10/2023
Capped in accordance with?: no data
Apparent mass of submerged cylinder 1: 0 lb
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 46580 lb
Maximum load on cylinder 2: 45760 lb
Maximum load on cylinder 3: 46880 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 0 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 3710.0 psi
Compressive strength of cylinder 2: 3640.0 psi
Compressive strength of cylinder 3: 3730 psi
Compressive strength (to nearest 10 psi): 3690 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/14/2023 ✔