Summary for Test 2017-01-23-1-33
Test performed: ASTM B499-14Project Information
| Project Identifiers | Project ID: 210041 DEA: 043G4864 EFIS: 0412000086 |
|---|---|
| DIST-CO-RTE-PM | 04-SM-92-14.4/18.8 |
| Award Date | 12/18/2015 |
| Closeout Date | 08/22/2018 |
| Work Description | CLEAN AND PAINT STRUCTURAL STEEL ON BRIDGE |
| Location Description | IN SAN MATEO AND ALAMEDA COUNTIES ON ROUTE 92 AT SAN MATEO HAYWARD |
| QA Service Level | 1 (Verified on 11/05/2014) |
Sample Information
| Sample Taken Date | 01/23/2017 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/24/2017 |
| Sample type | Quality Assurance | A brief description of the sample | Rocap Assembly |
| The quantity of what the sample constitutes | 7000 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Pacific Bolt Lejune Bolt | Transportation Laboratory (TL) Number | NA |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B900717 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | L1411737 Thru L1411740, L1411733 thru L1411736, L1411741 Thru L1411744, L1411690 Thru L1411692 |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | 24618-166642, PW721 | |
| Washer Mfg. Lot Number(s) | D2553, D2602 | Bolt Specification | ASTM A325 |
| Bolt Length(s) | Various | Nut Specification | ASTM A563 |
| Washer Specification | ASTM F436 | Finish | ASTM B695 - Mech Galv |
| Diameter/Size | 1in, 1.250 | Bolt Mfg. Lot Number | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2017-01-23-1
DIME Test ID: 2017-01-23-1-33
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2017-02-09
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 01/25/2017
Sample No.: 3A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 24616-166642
Finish Coating: ASTM B695 - Mech Galv
Product Markings: no data
Size: 1 in
Bolt Length: no data
Measurement Average: 3.1 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/2/2017 ✔