Summary for Test 2023-06-14-79-2
Test performed: AASHTO T209-22Project Information
Project Identifiers | Project ID: 994436 DEA: 11080284 EFIS: 1117000085 |
---|---|
DIST-CO-RTE-PM | 11-IMP-98-32.1/32.5 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Place HMA, minor concrete, modify drainage, landscape and electrical. |
Location Description | IMPERIAL COUNTY IN CALEXICO FROM OLLIE AVENUE TO 0.1 MILE EAST OF ROCKWOOD AVENUE |
QA Service Level | 1 (Verified on 12/09/2022) |
Sample Information
Sample Taken Date | 06/14/2023 | Sample Unique Key | 79 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/16/2023 |
Sample type | Quality Assurance | A brief description of the sample | 1-1/2" HMA |
The quantity of what the sample constitutes | 4 boxes 5 bags | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Loper |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | API Gateway | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | Not Applicable | Lot number | |
Sublot number | HMA Mix Number | 16 |
Test Details
DIME Sample ID: 2023-06-14-79
DIME Test ID: 2023-06-14-79-2
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-08-10
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Melchor Oronoz
Date of test: 07/21/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 10199.0 grams
Mass of oven-dry sample in air for Sample 1: 4056.6 grams
Mass of container filled with the sample and water for Sample 1: 12656.0 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.536
Theoretical maximum density at 25°C (77°F): 157.9 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/10/2023 ✔