Summary for Test 2023-07-21-44-8

Test performed: ASTM D4791-10

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/21/2023 Sample Unique Key44
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/28/2023
Sample typeVerification A brief description of the sample1/2" Aggregate
The quantity of what the sample constitutes6 Bags Of Aggregate From where was the sample collectedSource
First name of sampler or witnessed byErik Last name of sampler or witnessed bySvensson
Title of samplerConsultant Telephone number of sampler
Laboratory sample identification23-JMFPP-0149 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Bradshaw Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-34-0060
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedHMA Plant Cold Feed
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-07-21-44
DIME Test ID: 2023-07-21-44-8
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2023-08-10

Test Results


Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: B
Determination: By Mass
Dimensional ratio used: 5:1
Input Type: Calculated
Tester's full name: Ryan Kester
Date of test: 08/04/2023
Weighted percentage of particles (by mass) that were flat and elongated: 2 %
Weighted percentage of particles (by mass) that were not flat and elongated: 98 %
General comments (publicly viewable) (Max 1000 characters): Flat and elongated particles (% by mass at 5:1)

Test was verified on 8/10/2023