Summary for Test 2023-06-14-77-5
Test performed: AASHTO T283-14Project Information
| Project Identifiers | Project ID: 994436 DEA: 11080284 EFIS: 1117000085 |
|---|---|
| DIST-CO-RTE-PM | 11-IMP-98-32.1/32.5 |
| Award Date | Not set |
| Closeout Date | 10/24/2024 |
| Work Description | Place HMA, minor concrete, modify drainage, landscape and electrical. |
| Location Description | IMPERIAL COUNTY IN CALEXICO FROM OLLIE AVENUE TO 0.1 MILE EAST OF ROCKWOOD AVENUE |
| QA Service Level | 1 (Verified on 12/09/2022) |
Sample Information
| Sample Taken Date | 06/14/2023 | Sample Unique Key | 77 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/16/2023 |
| Sample type | Quality Assurance | A brief description of the sample | 1-1/2" HMA |
| The quantity of what the sample constitutes | 16 boxes 11 bags | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Loper |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | API Gateway | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | Not Applicable | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-06-14-77
DIME Test ID: 2023-06-14-77-5
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2023-08-09
Test Results
Unit system used?: SI Units
Input Type: Measured
Tester's full name: Melchor Oronoz
Date of test: 07/12/2023
| Wet 1 | Wet 2 | Wet 3 | Dry 1 | Dry 2 | Dry 3 | |
|---|---|---|---|---|---|---|
| Untreated | ||||||
| 150.0 mm | 150.0 mm | 150.0 mm | 150.0 mm | 150.0 mm | 150.0 mm | |
| 95.0 mm | 95.0 mm | 95.0 mm | 95.0 mm | 95.0 mm | 95.0 mm | |
| 3762.0 g | 3752.6 g | 3755.1 g | 3762.3 g | 3767.9 g | 3764.5 g | |
| 2181.7 g | 2185.5 g | 2174.9 g | 2195.2 g | 2194.6 g | 2189.9 g | |
| 3799.2 g | 3790.2 g | 3792.7 g | 3814.5 g | 3817.1 g | 3807.2 g | |
| 2.490 | 2.490 | 2.490 | 2.490 | 2.490 | 2.490 | |
| 3799.2 g | 3790.2 g | 3792.7 g | ||||
| 2181.7 g | 2185.5 g | 2174.9 g | ||||
| 95.2 mm | 95.3 mm | 95.2 mm | ||||
| 72 mmHg | 82 mmHg | 90 mmHg | ||||
| 0 inHg | 0 inHg | 0 inHg | ||||
| 5 minutes | 5 minutes | 5 minutes | ||||
1617.5 cm^3 | 1604.7 cm^3 | 1617.8 cm^3 | 1619.3 cm^3 | 1622.5 cm^3 | 1617.3 cm^3 | |
2.326 | 2.339 | 2.321 | 2.323 | 2.322 | 2.328 | |
6.6 % | 6.1 % | 6.8 % | 6.7 % | 6.7 % | 6.5 % | |
106.8 cm^3 | 97.9 cm^3 | 110.0 cm^3 | 108.5 cm^3 | 108.7 cm^3 | 105.1 cm^3 | |
3836.8 g | 3821.1 g | 3832.1 g | ||||
3847.4 g | 3830.9 g | 3843.1 g | ||||
1617.5 cm^3 | 1604.7 cm^3 | 1617.8 cm^3 | ||||
37.2 cm^3 | 37.6 cm^3 | 37.6 cm^3 | ||||
35 % | 38 % | 34 % | ||||
0.0 % | 0.0 % | 0.0 % | ||||
21320 N | 21267 N | 21801 N | 25684 N | 26680 N | 28615 N | |
1 | 1 | 1 | 1 | 1 | 1 | |
4 | 7 | 6 | 6 | 5 | 7 | |
0 | 0 | 0 | 0 | 0 | 0 | |
950 kPa | 947 kPa | 972 kPa | 1147 kPa | 1192 kPa | 1278 kPa | |
139 psi | 175 psi | |||||
0.79 | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/9/2023 ✔