Summary for Test 2023-06-14-93-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 994386
DEA: 023J7404
EFIS: 0222000079
DIST-CO-RTE-PM02-LAS-395-92.0/98.5
Award Date01/04/2023
Closeout Date04/11/2024
Work DescriptionHMA OVERLAY, REPLACE AC SURFACING AND RECESSED THERMOPLASTIC STRIPE.
Location DescriptionLASSEN COUNTY ABOUT 16 MILES SOUTH OF RAVENDALE FROM 0.1 MILE NORTH OF KARLO ROAD TO 1.5 MILES SOUTH OF RAMHORN ROAD
QA Service Level1 (Verified on 03/28/2023)

Sample Information

Sample Taken Date06/14/2023 Sample Unique Key93
Date that the sample was received by the laboratory/organization performing the testing06/15/2023 Sample typeVerification
A brief description of the sample2 bags of Untreated Washed Dust Sized Virgin Aggregate The quantity of what the sample constitutesJMF Verification
From where was the sample collectedSource First name of sampler or witnessed byAndrea
Last name of sampler or witnessed bySloaterman Title of samplerTET
Telephone number of sampler5306044726 Laboratory sample identificationD79266D
Linked DIME Sample ID The fabricator/manufacturer/facility nameHat Creek Construction and Materials - Ward Lake Pit - Litchfield, CA
Transportation Laboratory (TL) Number858028 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-18-0008::Ward Lake Pit
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedUntreated Sized Aggregate Stockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/8 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-06-14-93
DIME Test ID: 2023-06-14-93-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2023-08-08

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 06/19/2023
Cumulative Mass RetainedCumulative Percent Passing
1020.4 grams
grams %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
154.7 grams85 %
512.3 grams50 %
723.9 grams29 %
846.3 grams17 %
925.0 grams9 %
973.4 grams5 %
992.7 grams2.7 %
993.3 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/8/2023 ✔