Summary for Test 2016-12-27-5-1
Test performed: ASTM C39-10Project Information
| Project Identifiers | Project ID: 7285 DEA: 040120T4 EFIS: 0400000027 |
|---|---|
| DIST-CO-RTE-PM | 04-SF-80-12.6/13.9 |
| Award Date | 11/27/2012 |
| Closeout Date | 02/12/2025 |
| Work Description | CONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES |
| Location Description | THE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL |
| QA Service Level | 1 (Verified on 10/29/2012) |
Sample Information
| Sample Taken Date | 12/27/2016 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/30/2016 |
| Sample type | Verification | A brief description of the sample | 6 X 12 Concrete Cylinder |
| The quantity of what the sample constitutes | 10 cubic yards | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Carlos | Last name of sampler or witnessed by | Tongson |
| Title of sampler | TED | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Central Concrete | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | 340006 |
| Structure name | I80 Eastbound | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | D101C5E1 |
|---|---|---|---|
| The truck number from where the sample was collected | 1257 | The batch plant ticket number from where the sample was collected | 18338133 |
| Concrete batch plant | 12 | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | Concrete Truck | Where the material sample would have been placed if not sampled | Edge Beam Shear Key |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2016-12-27-5
DIME Test ID: 2016-12-27-5-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-01-24
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Bang
Date of test: 01/24/2017
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.97 in
Average diameter of cylinder 2: 5.99 in
Maximum load on cylinder 1: 164659 lb
Maximum load on cylinder 2: 175590 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Cross sectional area of cylinder 1: 27.99 in^2
Cross sectional area of cylinder 2: 28.18 in^2
Compressive strength of cylinder 1: 5882.8 psi
Compressive strength of cylinder 2: 6231.0 psi
Compressive strength (to nearest 10 psi): 6060 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 2
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 1/24/2017 ✔