Summary for Test 2023-07-20-54-4
Test performed: CTM 227-December 2014Project Information
Project Identifiers | Project ID: 215314 DEA: 07333004 EFIS: 0716000298 |
---|---|
DIST-CO-RTE-PM | 07-LA-5,5-15.1/22.9 |
Award Date | 10/20/2022 |
Closeout Date | Not set |
Work Description | PROJECT PILOT 1 |
Location Description | LOS ANGELES COUNTY IN AND NEAR LOS ANGELES ON ROUTE 5 FROM 0.1 MILE SOUTH OF CALZONA STREET TO 0.1 MILE SOUTH OF RIVERSIDE DRIVE AND ROUTE 2 AT LOS ANGELES REGIONAL TRANSPORTATION MANAGEMENT CENTER |
QA Service Level | 1 (Verified on 07/12/2021) |
Sample Information
Sample Taken Date | 07/20/2023 | Sample Unique Key | 54 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/21/2023 |
Sample type | Department Acceptance | A brief description of the sample | 1x4 PCC Aggregates |
The quantity of what the sample constitutes | 50 cy | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | victor | Last name of sampler or witnessed by | Pham |
Title of sampler | Telephone number of sampler | 2137924794 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | National-Vernon | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | United Rock-Irwindale |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Concrete backfill | The fabricator/manufacturer designation for the sample | mix S63C653T1 |
The plant number | Vernon | A detailed description of where the material sample was collected | Conveyor Belt |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | 63C653T1 | Lot number | |
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-07-20-54
DIME Test ID: 2023-07-20-54-4
Testing Lab: CT D07 - Plant Services
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2023-08-25
Test Results
Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Measured
Tester's full name: Victor Pham
Date of test: 07/27/2023
Top sediment column reading (single primary size): 0.4 in
Cleanness value (single primary size): 89
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/25/2023 ✔