Summary for Test 2023-06-27-69-3

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 214337
DEA: 080E33U4
EFIS: 0817000075
DIST-CO-RTE-PM08-SBD-115-R7.3/R10.0
Award Date04/26/2021
Closeout Date06/09/2025
Work DescriptionADD WB AUX & EB DECEL LANES, WIDEN I15 SW CONNECT,RAMPS/BRDG
Location DescriptionSAN BERNARDINO COUNTY IN ONTARIO FROM 0.2 MILE WEST OF CUCAMONGA CREEK BRIDGE TO MILLIKEN AVENUE
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date06/27/2023 Sample Unique Key69
Date that the sample was received by the laboratory/organization performing the testing06/30/2022 Sample typeQuality Assurance
A brief description of the sample4x8 cylinder The quantity of what the sample constitutes8 CYLINDERS
From where was the sample collectedJob Site First name of sampler or witnessed byVictor
Last name of sampler or witnessed byWami Title of samplerASR
Telephone number of sampler Laboratory sample identification1040-627
Linked DIME Sample ID The fabricator/manufacturer/facility nameBoral
Transportation Laboratory (TL) Number1040-627 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberRRM17031
The truck number from where the sample was collected1327 The batch plant ticket number from where the sample was collected7762007
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedTOP DECK OF CUCAMONGA CREEK BRIDGE Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-06-27-69
DIME Test ID: 2023-06-27-69-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2023-08-07

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 07/25/2023
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.01 in
Maximum load on cylinder 1: 80075 lb
Maximum load on cylinder 2: 80760 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Compressive strength of cylinder 1: 6370.3 psi
Compressive strength of cylinder 2: 6394.3 psi
Compressive strength (to nearest 10 psi): 6380 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/7/2023 ✔