Summary for Test 2023-06-09-17-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 994068 DEA: 081C7204 EFIS: 0813000003 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-R96.1/R124.3 |
Award Date | 08/02/2022 |
Closeout Date | 02/23/2024 |
Work Description | IMPORTED BORROW, SHOULDER BACKING, AND STRUCTURAL CONCRETE. |
Location Description | SAN BERNARDINO ABOUT 22 MILES NORTHEAST OF BARSTOW AT VARIOUS LOCATIONS FROM 0.3 MILE SOUTH OF HARVARD ROAD OVERCROSSING TO 0.1 MILE NORTH OF RASOR ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 09/30/2022) |
Sample Information
Sample Taken Date | 06/09/2023 | Sample Unique Key | 17 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/12/2023 |
Sample type | Quality Assurance | A brief description of the sample | Concrete Cylinders |
The quantity of what the sample constitutes | 3 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Alvin | Last name of sampler or witnessed by | Anggito |
Title of sampler | Assistant Structure Representative | Telephone number of sampler | |
Laboratory sample identification | 1047-612 | Linked DIME Sample ID | 2023-06-09-17 |
The fabricator/manufacturer/facility name | Robertsons | Transportation Laboratory (TL) Number | 081C720420230316 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | SC590838 |
---|---|---|---|
The truck number from where the sample was collected | 1954 | The batch plant ticket number from where the sample was collected | 7421420 |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Drainage System 19 Headwalls | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-06-09-17
DIME Test ID: 2023-06-09-17-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2023-08-07
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 07/21/2023
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.02 in
Average diameter of cylinder 2: 4.02 in
Average diameter of cylinder 3: 4.02 in
Maximum load on cylinder 1: 64180 lb
Maximum load on cylinder 2: 64670 lb
Maximum load on cylinder 3: 62840 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 42 days
Cross sectional area of cylinder 1: 12.69 in^2
Cross sectional area of cylinder 2: 12.69 in^2
Cross sectional area of cylinder 3: 12.69 in^2
Compressive strength of cylinder 1: 5057.5 psi
Compressive strength of cylinder 2: 5096.1 psi
Compressive strength of cylinder 3: 4951.9 psi
Compressive strength (to nearest 10 psi): 5040 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/7/2023 ✔