Summary for Test 2017-01-18-1-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210951
DEA: 120M3404
EFIS: 1212000017
DIST-CO-RTE-PM12-ORA-73,133-16.6,4.2
Award Date03/29/2016
Closeout Date06/17/2021
Work DescriptionWIDEN RAMP, CONSTRUCT RW AND DI, AND MODIFY LIGHTING
Location DescriptionNot set
QA Service Level1 (Verified on 03/30/2016)

Sample Information

Sample Taken Date01/18/2017 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing01/19/2017 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes4
From where was the sample collectedFabricator First name of sampler or witnessed byP
Last name of sampler or witnessed byPatel Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameRKR Steel Welding Cascade
Transportation Laboratory (TL) NumberC652020 Inspector Lot Number from the Transportation Laboratory (TL) FormL1100617
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)131715
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2017-01-18-1
DIME Test ID: 2017-01-18-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-01-30

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 01/20/2017
UTM: 75KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
131#5/16mm0.312964395620necking okayBrian

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 1/23/2017 ✔