Summary for Test 2023-06-14-68-5

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 994617
DEA: 112N1664
EFIS: 1122000153
DIST-CO-RTE-PM11-SD-79-44.7/53.0
Award Date05/18/2023
Closeout Date06/11/2024
Work DescriptionCOLD PLANE, RHMA OVERLAY, PAVEMENT MARKING, & RUMBLE STRIP.
Location DescriptionSAN DIEGO COUNTY NEAR SUNSHINE SUMMIT FROM 1.2 MILES NORTH OF ACORN CREEK BRIDGE TO RIVERSIDE COUNTY LINE
QA Service Level1 (Verified on 11/30/2023)

Sample Information

Sample Taken Date06/14/2023 Sample Unique Key68
Date that the sample was received by the laboratory/organization performing the testing06/20/2023 Sample typeVerification
A brief description of the sampleJMF 1/2" RHMA-OGFC The quantity of what the sample constitutes6 Bags Of Aggregate
From where was the sample collectedManufacturer First name of sampler or witnessed byDavid
Last name of sampler or witnessed byCarrera Title of sampler
Telephone number of sampler Laboratory sample identification0327O -23
Linked DIME Sample ID The fabricator/manufacturer/facility nameMartin Marietta-Lake Elsinore Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0098
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Martin Marietta Lake Elsinore Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size1/2 inch
The concrete mix design number51216090 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-06-14-68
DIME Test ID: 2023-06-14-68-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2023-09-12

Test Results


How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: M.Landaverde
Date of test: 06/28/2023
Clay Level (Test 1): 6.3
Sand Level (Test 1): 3.9
Clay Level (Test 2): 6.8
Sand Level (Test 2): 4.1
Clay Level (Test 3): 6.5
Sand Level (Test 3): 3.9
Sand Equivalent (Test 1): 62
Sand Equivalent (Test 2): 61
Sand Equivalent (Test 3): 60
Sand Equivalent: 61
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/12/2023 ✔