Summary for Test 2017-01-10-6-12
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 8196 DEA: 59912684 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | |
Location Description | |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 01/10/2017 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/13/2017 |
Sample type | Quality Assurance | A brief description of the sample | Prestressing Strand Group 10855 |
The quantity of what the sample constitutes | 79 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Hiranaga |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
---|---|---|---|
Reel/Coil/Pack Number(s) | Number of Coils | Unknown | |
Group Number | 10855 | Strand Diameter | .6 in |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | S0534116, S0577516, S0534916, S0535016, S0577416, S0534016, S0577616, S0534216, S0534816, S0534716, S0535116, S0577716, S0534316, S0577316, S0534416, S0288054, S0534516, | Mfg. Lot Number(s) | NA |
Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2017-01-10-6
DIME Test ID: 2017-01-10-6-12
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2017-01-30
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 01/17/2017
UTM: 120KIP
Temperature: 72 F
Extensometers: E88766
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | S0534016 | S333899-5 | 0.214 | 60376 | 54924 | 28.3 | 1.95 | Brian |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 1/23/2017 ✔