Summary for Test 2023-07-31-32-1
Test performed: AASHTO T59-22Project Information
| Project Identifiers | Project ID: 994556 DEA: 032G7604 EFIS: 0322000155 |
|---|---|
| DIST-CO-RTE-PM | 03-BUT-162-22.7/26.9,30.1/31.1 |
| Award Date | 04/18/2023 |
| Closeout Date | 05/09/2024 |
| Work Description | HMA (TYPE A), ROADWAY EXCAVATION, AND CLASS 2 AB. |
| Location Description | BUTTE COUNTY 4.7 MILES EAST OF OROVILLE FROM SADDLE DRIVE TO MIDDLE FORK FEATHER RIVER BRIDGE AND FROM CANYON CREEK BRIDGE TO FOREMAN CREEK ROAD |
| QA Service Level | 1 (Verified on 05/15/2023) |
Sample Information
| Sample Taken Date | 07/31/2023 | Sample Unique Key | 32 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/01/2023 |
| Sample type | Department Acceptance | A brief description of the sample | PMCRS-2h Emulsion & chipseal |
| The quantity of what the sample constitutes | 2 bottles of emulsion | From where was the sample collected | Source |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Romero |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | VSS Emultech | Transportation Laboratory (TL) Number | 778703 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphaltic Emulsion | Emulsion Grade | PMCRS-2h |
|---|---|---|---|
| Lot Number | Not set | Sub Lot | Not set |
| Dilution Percentage Rate | Not set |
Test Details
DIME Sample ID: 2023-07-31-32
DIME Test ID: 2023-07-31-32-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2023-08-03
Test Results
How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 08/02/2023
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 145.9 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 111.8 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 145.8 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 111.6 g
Beaker 1 Residue: 68.2 %
Beaker 2 Residue: 68.4 %
Percentage of residue: 68 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/3/2023 ✔