Summary for Test 2023-07-06-41-2
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 993409 DEA: 07327604 EFIS: 0716000132 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-39-32.2/38.4 |
| Award Date | 03/07/2022 |
| Closeout Date | 08/19/2025 |
| Work Description | INSTALL GUARDRAILS AND CONSTRUCT RETAINING WALLS. |
| Location Description | LOS ANGELES COUNTY NEAR AZUSA AT VARIOUS LOCATIONS FROM 0.3 MILE SOUTH OF NORTH FORK SAN GABRIEL RIVER OVERCROSSING TO 0.3 MILE NORTH CRYSTAL LAKE ROAD |
| QA Service Level | 1 (Verified on 12/06/2021) |
Sample Information
| Sample Taken Date | 07/06/2023 | Sample Unique Key | 41 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/13/2023 |
| Sample type | Production Start-Up | A brief description of the sample | 3/4" HMA-A-SP-R15 0.5% LAS |
| The quantity of what the sample constitutes | 20 Boxes of HMA | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Jons | Last name of sampler or witnessed by | QC |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0363A-23 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vulcan Irwindale | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 220831A IRW LTR | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-07-06-41
DIME Test ID: 2023-07-06-41-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-08-01
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Antonio Torres
Date of test: 07/15/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7330 grams
Mass of oven-dry sample in air for Sample 1: 2559.2 grams
Mass of container filled with the sample and water for Sample 1: 8872.2 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.516
Theoretical maximum density at 25°C (77°F): 2508.7 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/1/2023 ✔