Summary for Test 2013-08-09-10354146-6

Test performed: CTM 521-June 2012

Project Information

Project IdentifiersProject ID: 7780
DEA: 112T1824
EFIS: 1100020051
DIST-CO-RTE-PM11-SD-805-4.7/5.6
Award Date01/03/2013
Closeout Date09/07/2018
Work DescriptionREPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR).
Location DescriptionSAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING
QA Service Level1 (Verified on 12/10/2012)

Sample Information

Sample Taken Date08/09/2013 Sample Unique Key10354146
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/12/2013
Sample typeQuality Control A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes4 cylinders From where was the sample collectedSource
First name of sampler or witnessed byHalden Last name of sampler or witnessed byGeorge
Title of samplerNot set Telephone number of samplerNot set
Laboratory sample identification2013-08-09-1035 Linked DIME Sample IDNot set
The fabricator/manufacturer/facility nameVulcan Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeConcrete The concrete mix design number103612F
The truck number from where the sample was collectedNot set The batch plant ticket number from where the sample was collected146946
Concrete batch plantNot set The fabricator/manufacturer designation for the sampleNot set
A detailed description of where the material sample was collected316R Wall Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2013-08-09-10354146
DIME Test ID: 2013-08-09-10354146-6
Testing Lab: Vulcan Materials Company - San Diego
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2013-11-18

Test Results


Number of specimens:
Input Type: Calculated
Tester's full name: Christian Wheeler
Date of test: 10/10/2013
Correction factor: no data
Cylinder Age: 56 days
Break Description of Cylinder 1 (if not 'cone'): no data
Compressive Strength of Cylinder 1: 5050 lb/in^2
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/18/2013