Summary for Test 2023-07-21-42-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 994948
DEA: 072XH504
EFIS: 0723000280
DIST-CO-RTE-PM07---
Award DateNot set
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 07/21/2023)

Sample Information

Sample Taken Date07/21/2023 Sample Unique Key42
Date that the sample was received by the laboratory/organization performing the testing07/25/2023 Sample typeDepartment Acceptance
A brief description of the sample1x4 and WCS The quantity of what the sample constitutes16 Cy
From where was the sample collectedManufacturer First name of sampler or witnessed byvictor
Last name of sampler or witnessed byPham Title of sampler
Telephone number of sampler2137924794 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGL THROOP
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Martin Murietta-Irwindale
The fabricator's/manufacturer's product name for the sampleJPCP RSC The fabricator/manufacturer designation for the sampleMix 2010-007
The plant numberPasadena A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number2010-007 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-07-21-42
DIME Test ID: 2023-07-21-42-1
Testing Lab: CT D07 - Plant Services, Unit 1841
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2023-07-28

Test Results


What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Victor Pham
Date of test: 07/25/2023
Sieve SizeCumulative Mass RetainedCumulative Percent Passing
10270 grams
0.0 grams100 %
1036.0 grams90 %
3685.0 grams64 %
7278.0 grams29 %
9767.0 grams5 %
10201.0 grams1 %
10206.0 grams1 %
10270.0 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/28/2023 ✔