Summary for Test 2023-07-21-42-1
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 994948 DEA: 072XH504 EFIS: 0723000280 |
---|---|
DIST-CO-RTE-PM | 07--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 07/21/2023) |
Sample Information
Sample Taken Date | 07/21/2023 | Sample Unique Key | 42 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/25/2023 |
Sample type | Department Acceptance | A brief description of the sample | 1x4 and WCS |
The quantity of what the sample constitutes | 16 Cy | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | victor | Last name of sampler or witnessed by | Pham |
Title of sampler | Telephone number of sampler | 2137924794 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | GL THROOP | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Martin Murietta-Irwindale |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | JPCP RSC | The fabricator/manufacturer designation for the sample | Mix 2010-007 |
The plant number | Pasadena | A detailed description of where the material sample was collected | Stockpile @ Plant |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | 2010-007 | Lot number | |
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-07-21-42
DIME Test ID: 2023-07-21-42-1
Testing Lab: CT D07 - Plant Services
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2023-07-28
Test Results
What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Victor Pham
Date of test: 07/25/2023
Cumulative Mass Retained | Cumulative Percent Passing | |||||
---|---|---|---|---|---|---|
10270 grams | ||||||
0 grams | 100 % | |||||
1036 grams | 90 % | |||||
3685 grams | 64 % | |||||
7278 grams | 29 % | |||||
9767 grams | 5 % | |||||
10201 grams | 1 % | |||||
10206 grams | 1 % | |||||
10270 grams |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/28/2023 ✔