Summary for Test 2023-07-19-28-4

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/19/2023 Sample Unique Key28
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/10/2023
Sample typeQuality Assurance A brief description of the samplefastener Assembly
The quantity of what the sample constitutes300 From where was the sample collectedManufacturer
First name of sampler or witnessed byMike Last name of sampler or witnessed byHasler
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAmeron International Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)Bolt 1000113767 Nut 8000015546 Washer 32310130 Nut Mfg. Lot Number(s)W000013565
Washer Mfg. Lot Number(s)0523-742 Bolt SpecificationA325
Bolt Length(s)5.5 Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size1 Bolt Mfg. Lot Number476230A
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2023-07-19-28
DIME Test ID: 2023-07-19-28-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2023-08-10

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 07/26/2023
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11B98418Proof Load

General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 8/10/2023